The Triton XL series of dishwashers contain a
transient absorber (“transorb”). It absorbs electrical
transients created when the water valve is turned
off. The transorb is wired in the harness between
the line and neutral sides of the water valve circuit.
It is located approximately 1-1/2 inches from the red
water valve harness connector and is attached to a
yellow harness lead coming from the water valve on
one end and to a white-red neutral wire on the other
end. It is covered with black heat shrink tubing.
The kit number is WD35X10025.
It contains a transorb with 2 attached butt connectors
and installation instructions.
To install the new transorb, cut the defective part
out of the harness and splice in the new one.