Monday, December 27, 2010

LG Dryer Service Manual for Model DLG532W

LG Technical Service Manual For Model DLG5932W

Kenmore dryer motor replacement.

Wednesday, December 22, 2010

How to diagnose electronic furnace ignition

How to diagnose Robertshaw electronic pilot ignition

Taurus MAF check





With the key ON , and the engine OFF , verify that there is at least 10.5 volts ( I got 11.65)between the VPWR (red) and GND (black/white) terminals of the MAF sensor connector. If voltage is not within specification, check power and ground circuits and repair as necessary.
With the key ON , and the engine ON , verify that there is at least 4.5 volts between the SIG (light blue/red) and GND terminals of the MAF sensor connector.(I got 0.68) If voltage is not within specification, check power and ground circuits and repair as necessary.
With the key ON , and the engine ON , check voltage between GND and SIG RTN (tan/light blue) terminals. Voltage should be approximately 0.34-1.96 volts. (I got .009)If voltage is not within specification, the sensor may be faulty. This was with the maf unplugged and engine running. Engine runs slightly better with MAF plugged back in. What yall thank ? I appreciate yalls help very much.